Service 1 of 2
Cellulose Insulation
A versatile blown-in insulation option suitable for attics, wall cavities and a variety of new-construction or retrofit projects throughout Southwestern Ontario.
What is Cellulose?
Dense, Recycled & Sound-Dampening
Cellulose insulation is manufactured from recycled paper fibres treated with fire retardants. It is blown into attics and dense-packed into wall cavities, conforming around wires, pipes and irregular framing to eliminate voids and air gaps.
Its higher density gives cellulose strong thermal performance and genuine sound-control potential—ideal for shops, livestock facilities, and homes where noise and temperature control both matter.
- Coverage around irregular spaces
- High thermal performance
- Suitable for existing and new structures
- Efficient blown-in installation
- Sound-control potential
- Made from recycled paper content

Common Applications
Attic Top-Ups
Add depth over existing insulation to boost R-value.
Enclosed Wall Cavities
Dense-pack cellulose into retrofit wall assemblies.
New Construction
Blown into newly framed ceilings before drywall.
Agricultural Shops
Insulate farm shop ceilings and storage buildings.
Technical Specifications
Climatizer Plus™ Attic Coverage Chart
Romulus Enterprises installs premium Canadian-manufactured Climatizer Plus™ blown-in cellulose fiber insulation. Below are official manufacturer coverage specifications and thickness standards (CCMC Evaluation 09217-L).
1.6 lb/cu.ft.
24.9 kg/m³ settled density
12.4″ applied
11.1″ settled depth · 47.7 bags/1,000 ft²
30 lbs
13.61 kg / bag · Formula D
| Thermal Resistance (RSI / R) | Applied Depth | Settled Depth | Coverage / Bag | Bags / 1,000 sq.ft. |
|---|---|---|---|---|
R-10(RSI 1.7) | 3.0″ (76mm) | 2.7″ (68mm) | 86.2 ft² | 11.6 |
R-12(RSI 2.1) | 3.7″ (94mm) | 3.3″ (84mm) | 69.8 ft² | 14.3 |
R-15(RSI 2.6) | 4.6″ (116mm) | 4.1″ (104mm) | 56.7 ft² | 17.6 |
R-20(RSI 3.5) | 6.2″ (157mm) | 5.5″ (141mm) | 41.9 ft² | 23.9 |
R-25(RSI 4.4) | 7.8″ (198mm) | 7.0″ (177mm) | 33.3 ft² | 30.0 |
R-30(RSI 5.3) | 9.4″ (238mm) | 8.4″ (213mm) | 27.6 ft² | 36.2 |
R-32(RSI 5.6) | 9.9″ (252mm) | 8.9″ (225mm) | 26.2 ft² | 38.2 |
R-40(RSI 7.0)Common Code Target | 12.4″ (314mm) | 11.1″ (281mm) | 21.0 ft² | 47.7 |
R-50(RSI 8.8)High Efficiency | 15.6″ (396mm) | 13.9″ (354mm) | 16.6 ft² | 60.1 |
R-60(RSI 10.6)Max Performance | 18.8″ (478mm) | 16.8″ (426mm) | 13.8 ft² | 72.3 |
R-70(RSI 12.3) | 21.8″ (554mm) | 19.5″ (495mm) | 11.9 ft² | 84.0 |
Calculated for dry pneumatic attic installations. Complies with CCMC Evaluation 09217-L and CIMA standards.